§ 25-86. Specific conditions and cross-connection control.
(a)
Before any chemical is added to an irrigation system connected to the potable water supply, the irrigation system must be connected through a reduced pressure principle backflow prevention assembly or air gap.
(b)
Connection of any additional water source to an irrigation system that is connected to the potable water supply can only be done if the irrigation system is connected to the potable water supply through a reduced-pressure principle backflow prevention assembly or an air gap.
(c)
Irrigation system components with chemical additives induced by aspiration, injection, or emission system connected to any potable water supply must be connected through a reduced pressure principle backflow device.
(d)
If an irrigation system is designed or installed on a property that is served by an on-site sewage facility, as defined in title 30, Texas Administrative Code, chapter 285, then:
(1)
All irrigation piping and valves must meet the separation distances from the on-site sewage facilities system as required for a private water line in title 30, Texas Administrative Code, section 285.91(10);
(2)
Any connections using a private or public potable water source that is not the city's potable water system must be connected to the water source through a reduced pressure principle backflow prevention assembly as defined in title 30, Texas Administrative Code, section 344.50; and
(3)
Any water from the irrigation system that is applied to the surface of the area utilized by the on-site sewage facility system must be controlled on a separate irrigation zone or zones so as to allow complete control of any irrigation to that area so that there will not be excess water that would prevent the on-site sewage facilities system from operating effectively.
(Ord. No. 2010-O-026, § 2(G), 3-1-10)